To further enhance a building's room climate, acoustic performance and thermal performance, an AERCON roof panel system is the best solution to attain all of these characteristics. AERCON roof panels can be installed on a slope or horizontal. The thermal effects, within the building, from the summer and winter temperatures are minimized. Similar to AERCON floor panels, AERCON roof panels weigh less than other concrete roof systems. Therefore, a reduction in the size and weight of the building foundation system may be possible.

Another distinct advantage of using AERCON roof panels is the speed of installation. A roof area up to 40 ft2 is easily installed with one crane lift utilizing a welltrained erection crew. The fireresistant characteristics for AERCON are exceptional.

Fabrication

Roof panels are supplied on the basis of Strength Class AC4 and AC6. The maximum panel length is 20'-0". The standard panel width is 2'-0". A nominmal panel thickness of 8", 10" or 12" is available depending on the loading and span requirements.

Panel System

Roof panels are tailor made. Their length, thickness and reinforcement are determined based on the building requirements and specifications. The standard panel width is 2'-0". See the Overview Section for panel profile information.

Panel Cutting and Openings

All panels may be cut and may contain openings throughout the panel. However, the size, location and type of cut or opening should be coordinated with AERCON prior to the design phase to avoid any unnecessary field modifications. The reason for this is that every opening, notch or cut (round, rectangular, diagonal) causes additional stress on the area around the potential cut. Any additional reinforcement requirements can be taken into account during the design and fabrication process.

Roof Panel Cuttings and Openings

Panel Thickness

The thickness of AERCON roof panels depends on the required span and loads.

Also, the panel thickness may be influenced by the thermal or acoustical insulation requirements in conjunction with the required dead and live loads.

The following typical loads may be used for calculating the panel thickness. However, all panels are designed based on the project requirements, as specified by the Design Professional.

Weight of the roof panel
39 pcf for AC4
49 pcf for AC6
Dead Loads
Roofing 15 psf
Ceiling/Mech. 10 psf
Live Loads
Roof 20 psf

For non-standard loads and related questions, consult an AERCON Representative. Check all local jurisdictional requirements for any additional or differing required design loads.

The graph below shows representative spans for a range of live loads. This graph may be used for the preliminary determination of the thickness required for a particular project. Since roof panels are uniquely designed for a project, the maximum span for an individual panel may deviate from the graphical value.

Roof Structure Graph

Deflection

The allowable deflection of AERCON roof panels, due to the total load, is L/180. The allowable deflection for the live load is L/240.

Support

The length of bearing required for AERCON roof panels is 21/2" minimum.

Grouting

The key joints at adjacent panels are filled with cement grout in order to provide a positive diaphragm shear transfer.

Roof Shapes

Traditional flat or sloped roofs are possible with AERCON roof panels. The roof slope for drainage can be achieved by sloping the support framing of the underlying structure or by providing a layer of tapered insulation (the traditional method) on the roof panels.

 
 

**Refer to chart for Dimensions and Strength Classes

Roof

- Assembly and Erection
- Structural Design
- Construction

Floor

- Assembly and Erection
- Structural Design
- Construction

Horizontal

- Assembly and Erection
- Structural Design
- Construction

Vertical

- Assembly and Erection
- Structural Design
- Construction

Interior

- Construction

Lintel and Blocks

- Assembly and Erection
- Structural Design
- Construction